we provide Refined Cisco 010-151 exam cost which are the best for clearing 010-151 test, and to get certified by Cisco Cisco Certified Technician (CCT) for Data Center. The 010-151 Questions & Answers covers all the knowledge points of the real 010-151 exam. Crack your Cisco 010-151 Exam with latest dumps, guaranteed!

Free 010-151 Demo Online For Cisco Certifitcation:

NEW QUESTION 1
To do a password recovery on a Cisco NX-OS Switch, which option shows the correct syntax to display the bootflash contents at the switch(boot)#?

  • A. display bootflash:
  • B. show bootflash:
  • C. dir bootflash:
  • D. find bootflash:

Answer: C

NEW QUESTION 2
What does the system status LED look like when an over temperature or major alarm occurs on the Cisco UCS 6120XP Fabric Interconnect?

  • A. Amber
  • B. Red
  • C. Blinking amber
  • D. Blinking red

Answer: C

NEW QUESTION 3
Which two statements about the Cisco Nexus 5596UP switch are true? (Choose two.)

  • A. Its power supplies and fan trays are hot-swappabl
  • B. It supports unified port
  • C. It is offered in a one-rack-unit form facto
  • D. It has one expansion slo
  • E. It supports up to 96 10G BASE-T port

Answer: AB

NEW QUESTION 4
Which three firmware components does the Host Upgrade Utility upgrade? (Choose three.)

  • A. Fabric Interconnect firmware
  • B. LAN on Motherboard
  • C. Cisco UCS Manager
  • D. CIMC
  • E. System BIOS

Answer: BDE

NEW QUESTION 5
Which supervisor module is supported by a Cisco Nexus 7700 Series Switch?

  • A. first-generation supervisor module
  • B. second-generation supervisor module (Sup2)
  • C. second-generation supervisor enhanced module (Sup2E)
  • D. third-generation supervisor enhanced module (Sup3E)

Answer: C

NEW QUESTION 6
DRAG DROP
010-151 dumps exhibit

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
010-151 dumps exhibit

NEW QUESTION 7
Which type of optics module is supported by a 6-port 40 GE Cisco Nexus 7000 M2 Series I/O module?

  • A. CPAK
  • B. QSFP+
  • C. SFP/SFP+
  • D. CFP

Answer: B

NEW QUESTION 8
When the Cisco UCS Manager is used to verify the B- or C-Series device, which two types of Overall Status are acceptable and do not indicate a failure? (Choose two.)

  • A. Online
  • B. OK
  • C. Unassociated
  • D. Active

Answer: BC

NEW QUESTION 9
Which two major components does a Cisco Nexus 1000V Series Switch have? (Choose two.)

  • A. Virtual Fiber Channel Module
  • B. Virtual Ethernet Module
  • C. Virtual Supervisor Module
  • D. Virtual Memory Controller Module
  • E. Virtual Network Module

Answer: BC

NEW QUESTION 10
Which three steps do you perform to troubleshoot when a rack server powers on with no video? (Choose three.)

  • A. Check that the front I/O dongle is properly seate
  • B. Check the front I/O cable connection to the motherboar
  • C. Check for memory subsystem failur
  • D. Verify the power source to equipmen
  • E. Reseat the DIMMs, CPU, and PCI card

Answer: ABC

NEW QUESTION 11
Which command syntax is correct to reset the admin password when the switch is in the kickstart prompt "switch(boot) #"?

  • A. exec -> admin-password <password>
  • B. connect local-mgmt -> admin-password <password>
  • C. configure terminal -> admin-password <password>
  • D. connect nxos -> admin-password <password>
  • E. admin-password <password>

Answer: C

NEW QUESTION 12
Which processor option is supported in the Cisco UCS C420 M3 Server?

  • A. up to two Intel Xeon E5-4600 series multicore processors
  • B. up to two Intel Xeon E7-4800 series multicore processors
  • C. up to four Intel Xeon E5-4600 series multicore processors
  • D. two or four Intel Xeon E7-8800 series multicore processors

Answer: C

NEW QUESTION 13
Which three tools are necessary to console into a Cisco UCS C-Series Rack-Mount Server? (Choose three.)

  • A. Cisco DB-9-to-RJ-45 console cable
  • B. laptop
  • C. monitor
  • D. keyboard
  • E. KVM dongle
  • F. USB serial adapter

Answer: CDE

NEW QUESTION 14
Refer to the exhibit.
010-151 dumps exhibit
What is the name of this rack-mount server?

  • A. Cisco UCS C220 Rack-Mount Server
  • B. Cisco UCS C240 Rack-Mount Server
  • C. Cisco UCS C420 Rack-Mount Server
  • D. Cisco UCS C460 Rack-Mount Server

Answer: C

NEW QUESTION 15
When a host firmware package policy is created, what must it be associated with to upgrade the BIOS?

  • A. blade or blade pool
  • B. service profile
  • C. boot policy
  • D. service template

Answer: B

NEW QUESTION 16
If the Overall Status for a Cisco UCS B-Series Blade Server indicates a failure in the Cisco UCS Manager, such as discovery-failed, which statement is true?

  • A. The server shuts dow
  • B. The server automatically reboots reboot in 3 minute
  • C. The endpoints on that server cannot be upgrade
  • D. The server is online, but the administrator cannot assign a service profile to that blad

Answer: C

NEW QUESTION 17
Refer to the exhibit.
010-151 dumps exhibit
Which statement correctly identifies the front panel LEDs on the Cisco UCS C220 Server?

  • A. A is power button and power status LED; B is identification button and LED; C is system status LED; D is network link activity LE
  • B. A is network link activity LED; B is system status LED; C is power button and power status LED; D is identification button and LE
  • C. A is system status LED; B is network link activity LED; C is power button and power status LED; D is identification button and LE
  • D. A is network link activity LED; B is system status LED; C is identification button and LED; D is power button and power status LE

Answer: A

NEW QUESTION 18
Which two commands allow you to view the state of high availability between the two clustered Fabric Interconnects? (Choose two.)

  • A. show cluster state extended
  • B. show cluster extended-state
  • C. show cluster HA status
  • D. show cluster state

Answer: BD

NEW QUESTION 19
Refer to the exhibit.
010-151 dumps exhibit
Where is the best place to see the power supply status of the blade server enclosure?

  • A. A - Chassis 1
  • B. B - Chassis 1 - PSUs
  • C. C - Chassis1 - Servers
  • D. D - Rack-Mounts - Servers
  • E. E - Fabric Interconnects A - PSUs

Answer: B

NEW QUESTION 20
After installation or replacement of a Cisco UCS C-Series Rack-Mount Server, the host does not boot.
Which four options should be verified? (Choose four.)

  • A. Verify the power source to the equipmen
  • B. Check for loose HDD cable
  • C. Reseat the DIMMs, CPU, and PCI card
  • D. Verify that power supplies are receiving powe
  • E. Reseat the mezzanine card connecto
  • F. Check the CPU sockets for bent pin
  • G. Check the Cisco IMC for fan fault

Answer: ACDF

NEW QUESTION 21
Up to what speed can Category 5e UTP cable transmit data?

  • A. 10 Mb/s
  • B. 100 Mb/s
  • C. 1000 Mb/s
  • D. 10000 Mb/s

Answer: C

NEW QUESTION 22
Which five things should the administrator verify after performing maintenance or replacing a blade server? (Choose five.)

  • A. blade server status
  • B. hard drive status
  • C. host OS boot status
  • D. CPU status
  • E. mezzanine card status
  • F. memory DIMM status
  • G. fan and power status

Answer: ABDEF

NEW QUESTION 23
Which three statements about powering down a Cisco UCS C-Series Rack-Mount Server to perform maintenance or replacement are true? (Choose three.)

  • A. Standby power mode: Power is supplied only to the service processor and the cooling fans, and it is safe to power off the server from this mod
  • B. Power status LE
  • C. Green indicates that the server is in main power mode and can be safely powered of
  • D. Graceful shutdown: Press and release the power butto
  • E. The operating system performs a graceful shutdown, and the server goes to standby mode, which is indicated by an amber power status LE
  • F. Disconnect the power cords from the power supplies in your server to completely power off the serve
  • G. Only an emergency shutdown can be performed using the power button on the server front pane
  • H. The Cisco UCS C-Series Rack-Mount Server has only one power mod

Answer: ACD

NEW QUESTION 24
Which three troubleshooting procedures do you perform when there is no power to a Cisco UCS B250 M2 Blade Server? (Choose three.)

  • A. Decommission and acknowledge the blad
  • B. Check the back of the blade to ensure that there is no damage to the connection that goes into chassi
  • C. Reseat the memory DIMM
  • D. Check the CPU sockets for bent pin
  • E. Reseat the blade in the same slot in the chassi
  • F. Move the blade to another slot in the chassi

Answer: BEF

NEW QUESTION 25
Which method is a TCP/IP-based protocol for establishing and managing connections between IP-based storage devices, hosts, and clients?

  • A. FCIP
  • B. iFCP
  • C. iSCSI
  • D. FCoE

Answer: C

NEW QUESTION 26
......

Thanks for reading the newest 010-151 exam dumps! We recommend you to try the PREMIUM Dumpscollection 010-151 dumps in VCE and PDF here: http://www.dumpscollection.net/dumps/010-151/ (72 Q&As Dumps)