NEW QUESTION 1
You modified a logical interconnect group mat is used to configure logical interconnects in five different logical enclosures. What will be the impact of that change?
- A. All physical interconnects from affected logical interconnects will be placed in a maintenance mode
- B. All physical interconnects from the affected logical interconnects must he rebooted to activate the new configuration
- C. All logical interconnects configured using this logical Interconnect group will report inconsistency
- D. All logical interconnects configured using this logical interconnect group will be automatically updated
Answer: A
NEW QUESTION 2
You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group
What should you check to fix the issue?
- A. if both FiexNICs are configured with the same speed
- B. If the logical enclosure is built on at least three HPE Synergy frames
- C. if both FiexNICs are connected to different networks
- D. if the logical enclosure is configured with redundant master modules
Answer: A
NEW QUESTION 3
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex 280 They plan to manage new components using HPE OneView
What must be done to achieve this goal?
- A. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView
- B. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
- C. The customer must add a second Rack Management Controller for HPE Superdome Flex 280
- D. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy
Answer: C
NEW QUESTION 4
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?
- A. Virtual Distributed Switch
- B. vSphere Standard license
- C. Load balancing cluster
- D. Dedicated VMKernel port
Answer: D
NEW QUESTION 5
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames
How will this change impact the customer environment?
- A. The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.
- B. The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
- C. The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
- D. The customer can add a new logical enclosure to an existing setup once all required licenses are addedlo HPE OneView and associated with the new frames.
Answer: A
NEW QUESTION 6
Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis Which components must be included in the proposal to meet the customer’s needs?
- A. Rack Management Controller for nPar management
- B. HPE Superdome Flex Grid licenses enabling connectivity between chassis
- C. At least Tour HPE Persistent Memory DIMMs per nPar
- D. One base chassis and three expansion chassis with licenses
Answer: D
NEW QUESTION 7
Your customer plans to manage HPE Primera using HPE Oneview
Which storage management tasks can be completed using HPE OneView for this environment?
- A. CPG management
- B. Volume provisioning
- C. Cache management
- D. Replication setup
Answer: B
NEW QUESTION 8
Your customer wants to compare HPE Superdome Flex with HPE Superdome Flex 280. Which statement about these two systems is true?
- A. Only HPE Superdome Rex 280 can be managed using HPE OneView
- B. Only HPE Superdome Flex supports HPE Persistent Memory
- C. Only HPE Superdome Flex 280 can support multiple nPars
- D. Only HPE Superdome Flex supports 32 sockets and 48TB of memory
Answer: A
NEW QUESTION 9
Which statement about login redistribution is true?
- A. Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame
- B. Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports
- C. Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules
- D. Login redistribution is used for login balancing when they are not distributed evenly over the FC links
Answer: C
NEW QUESTION 10
In the past a customer experienced a networking issue where network ports went down and came back up in quick succession.
Which HPE Virtual Connect SE 100 GD F32 Module for HPE Synergy feature can be configured to disable such ports?
- A. Pause flood protection
- B. sFlow
- C. Storm control
- D. Port flap protection
Answer: B
NEW QUESTION 11
Which statement about an HPE Oneview support dump is true?
- A. Appliance support dump by default contains a logical enclosure support dump
- B. Support dump is a binary file that can be opened only in a dedicated application
- C. Support dump can be created if HPE Virtual Connect modules are installed in the frame
- D. Preview support dump is available only when creating an appliance support dump
Answer: B
NEW QUESTION 12
Which statement about manual orchestration during the firmware update is true?
- A. It is supported only for logical enclosures with at least three frames
- B. It provides an ability to select and update one side of the Interconnect topology at a time
- C. It provides the ability to install an older firmware version than currently Installed In the interconnect
- D. It allows all the interconnect modules to be activated manually at the same time.
Answer: B
NEW QUESTION 13
Refer to the exhibit.
Which statement about this logical JBOD is true?
- A. This logical JBOD can be connected to multiple systems to formulate a snared datastore.
- B. After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created
- C. After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done
- D. This logical JBOD can be presented to the compute nodes in a different frame.
Answer: C
NEW QUESTION 14
As a result of the troubleshooting process, you recommend replacing, HPE Synergy Composer modules which HPE Synergy Composer 2
Why would you recommend this change?
- A. HPE Composer 1 running HPE OneView 5 2 or later can support only 12 frames within a single management nog
- B. HPE Composer 2 can support more than the maximum 21 frames that are supported with HPE Composer 1 and HPE OneView.
- C. HPE Composer 2 provides access to 105 interface that can be used for full management of HPE Composer 2 remotely
- D. HPE Composer 1 cannot support remote frames, which doubles the configuration and management procedures effort
Answer: B
NEW QUESTION 15
Your customer has a logical enclosure configured using a angle HPE Synergy frame with the following configuration
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- two HPE Synergy Virtual Connect SE 32Gb FC Modules -12 HPE Synergy 480 Gen10 Plus compute nodes with appropriate mezzanine cards
They plan to add a new HPE Synergy frame to an existing logical enclosure with the following configuration
- two HPE Synergy Virtual Connect SE 32Gb FC Modules
- two HPE Synergy 20Gb interconnect Link Modules
- Eight HPE Synergy 480 Gen 10 Plus compute nodes with appropriate mezzanine cards Which statement about the planned configuration change is true?
- A. Four compute modules must be moved to the second frame to balance the configuration
- B. The two HPE Synergy 20Gb interconnect Link Modules must be replace with the 50Gb option
- C. A license for an extended logical enclosure must be added to HPE OneView through GUI
- D. The HPE Synergy virtual Connect SE 32Gb FC Modules from both frames should be stacked
Answer: D
NEW QUESTION 16
......
100% Valid and Newest Version HPE0-S60 Questions & Answers shared by 2passeasy, Get Full Dumps HERE: https://www.2passeasy.com/dumps/HPE0-S60/ (New 79 Q&As)