Your success in Network-Appliance NS0-520 is our sole target and we develop all our NS0-520 braindumps in a way that facilitates the attainment of this target. Not only is our NS0-520 study material the best you can find, it is also the most detailed and the most updated. NS0-520 Practice Exams for Network-Appliance NS0-520 are written to the highest standards of technical accuracy.

Network-Appliance NS0-520 Free Dumps Questions Online, Read and Test Now.

NEW QUESTION 1

You install an ASA AFF A400 system with 32 GB FC SFP+ modules in port 0e and 0f. After creating the SVM and configuring the FCP protocol, the physical port stays offline. Referring to the exhibit which statement is correct?
NS0-520 dumps exhibit

  • A. The current type of the ports must be configured as an initiator
  • B. The current mode to the ports must be configured as an FC port
  • C. The current mode for the ports must be set as an NVMe/FC port
  • D. The admin status is manually set to down

Answer: B

Explanation:
Before using your UTA ports on a FC infraestructure, you need to modify the current mode from CNA to FC. You need to set the ports offline before you modify that parameter.
You can find more information on this link:
http://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-E2CD31BE-28E

NEW QUESTION 2

In a Linux environment, issues are reported concerning multipathing. You want to view the direct and indirect paths. In this scenario, which command would you use to accomplish this task?

  • A. Use the lspci command
  • B. Use the systemctl command
  • C. Use the ifconfig command
  • D. Use the sanlun command

Answer: D

Explanation:
C:\Users\Admin\Desktop\Data\Odt data\Untitled.jpg
NS0-520 dumps exhibit

NEW QUESTION 3

You are designing a new 4-node AFF A400 SAN cluster with 20 ISCSI hosts. Each AFF A400 node will have four data LIFs. Each ISCSI host needs to access every LUN over two LIFs per node on every
SAN node.
In this scenario, which Netapp SAN feature enable this connectivity?

  • A. Port sets
  • B. HBA queue depth
  • C. Selective LUN mapping
  • D. Asymmetric namespace

Answer: A

Explanation:
SLM will choose 4 LIFs per node, being 8 LIF total (owner and HA partner), enabling portsets will help to limit the ports per node... that way we can stablish only 2 LIF per node.
Creating port sets and binding igroups to port sets
In addition to using Selective LUN Map (SLM), you can create a port set and bind the port set to an igroup to further limit which LIFs can be used by an initiator to access a LUN. If you do not bind a port set
to an igroup, then all of the initiators in the igroup can access mapped LUNs through all of the LIFs on the node owning the LUN and the owning node's HA partner.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-5CC27202-A43

NEW QUESTION 4

You need to move a LUN non-disruptively from an AFF A200 HA pair to an AFF A700 HA pair within the same 4-node cluster using the steps shown below.
* 1. Scan the host OS to discover all paths to the LUN.
* 2. Execute the lun move command to move the LUN to the AFF A/00 HA pair.
* 3. Remove the AFF A200 HA pair from the reporting-nodes list.
* 4. Add the AFF A700 HA pair to the reporting-nodes list. What is the correct sequence in performing, these steps?

  • A. 1, 2, 3. 4
  • B. 4. 1, 2, 3
  • C. 4, 3. 2. 1
  • D. 3, 2, 1,4

Answer: B

NEW QUESTION 5

An administrator has six VMware hosts, each with dual HBAs that are connected to a dual fabric using single initiator multiple target zoning. Four nodes are being added to the existing 4-node ONTAP cluster.
In this scenario, what is the minimum number of FC zones that need to be updated on each fabric switch?

  • A. 6
  • B. 8
  • C. 4
  • D. 2

Answer: B

NEW QUESTION 6

NS0-520 dumps exhibit
A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. Referring to the exhibit, what will happen?

  • A. The NVMe namespaces on AFF_2 will be available after takeover of AFF_1.
  • B. The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover.
  • C. The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1.
  • D. The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2.

Answer: C

NEW QUESTION 7

A company wants to use jumbo frames to improve performance with their iSCSI network. When setting up the Ethernet switches for jumbo frames, which three components need to be configured? (Choose three.)

  • A. Ethernet port on Management Console
  • B. Ethernet port on RLM
  • C. Ethernet port on host system
  • D. Ethernet port on storage device
  • E. Ethernet port on FC switch
  • F. Ethernet switch ports being used

Answer: CDF

NEW QUESTION 8

Which NetApp tool provides a detailed inventory of SAN components?

  • A. Active IQ OneCollect
  • B. Interoperabilty Matrix Tool
  • C. Active IQ config advisor
  • D. Hardware Universe

Answer: A

Explanation:
ActiveIQ OneCollect is a tool from NetApp that will create an inventory of your environment that will include hosts, switches and storage and validate it against the IMT (Interoperability Matrix Tool).

NEW QUESTION 9

You are planning to expand a SAN-only ONTAP 9.5 cluster that consists of eight AFF A700 nodes. In this scenario, what is the maximum number of additional AFF A700 nodes that would be added?

  • A. 2
  • B. 4
  • C. 8

Answer: B

NEW QUESTION 10

While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed:
NS0-520 dumps exhibit
What is the cause of this error?

  • A. The volume auto-grow is disabled.
  • B. The LUN reached maximum capacity.
  • C. The LUN can be expanded up to 10 times its original size.
  • D. Space reservation is enabled.

Answer: A

NEW QUESTION 11

NS0-520 dumps exhibit
You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI protocol is enabled.
Referring to the exhibit, what is needed to allow hosts to log into the iSCSI target?

  • A. Create new LIFs with the iSCSI data protocol.
  • B. Create new igroups with the host IQNs.
  • C. Add iSCSI to the data protocol of the existing LIFs.
  • D. Map LUNs to the igroups.

Answer: D

NEW QUESTION 12

At which storage object level is deduplication enabled?

  • A. Aggregate
  • B. Volume
  • C. Qtree
  • D. LUN

Answer: B

NEW QUESTION 13

Which option needs to be set on a LUN to guarantee that it cannot be affected by other LUNs in the volume?

  • A. Volume Guarantee
  • B. Volume Space Reserved
  • C. LUN Reservation Disabled
  • D. LUN Reservation Enabled

Answer: D

NEW QUESTION 14

Exhibit.
NS0-520 dumps exhibit
You want to map a LUN to a server.
To which SAN object is the highlighted value in the exhibit added?

  • A. LUN
  • B. fabric zone
  • C. FlexClone
  • D. igroup

Answer: D

NEW QUESTION 15

Your server administrator upgraded a Windows 2016 Server from 16 Gb to 32 Gb HBAs. The application owner is now reporting slower performance to the AFF A700.
Which two actions will help troubleshoot performance on the server? (Choose two.)

  • A. Verify the HBA model using Hardware Universe.
  • B. Verify the HBA firmware using the Interoperability Matrix Tool.
  • C. Confirm that LUN mapping exists.
  • D. Confirm that Windows Host Utilities Is installed.

Answer: AB

NEW QUESTION 16

After completing the configuration of a new Brocade Fibre Channel switch, which command do you use to verify your configuration?

  • A. switchshow
  • B. show config
  • C. configshow
  • D. cfgshow

Answer: C

NEW QUESTION 17

Which two features does Assymmetric Namespase Access (ANA) support? (Choose two.)

  • A. multipathing
  • B. LUN masking
  • C. LUN hosting
  • D. path management

Answer: AD

NEW QUESTION 18
......

Thanks for reading the newest NS0-520 exam dumps! We recommend you to try the PREMIUM Dumpscollection.com NS0-520 dumps in VCE and PDF here: https://www.dumpscollection.net/dumps/NS0-520/ (234 Q&As Dumps)