We provide in two formats. Download PDF & Practice Tests. Pass Cisco 300-175 Exam quickly & easily. The 300-175 PDF type is available for reading and printing. You can print more and practice many times. With the help of our product and material, you can easily pass the 300-175 exam.

Free demo questions for Cisco 300-175 Exam Dumps Below:

NEW QUESTION 1
You need to identify which DCB standard provides these functionalities: negotiation capabilities for features, the distribution of parameters from one node to another, and logical link up and down signaling for both Ethernet and Fibre Channel interfaces.
Which DCB standard should you identify?

  • A. ETS
  • B. PFC
  • C. DCBX
  • D. QCN

Answer: C

NEW QUESTION 2
Open the windows by clicking on the minimized at the bottom of the viewing area. Windows can be minimized by clicking on the [X], repositioned by dragging the title bar, and resized by using the handle at the lower right corner to customize the viewing area.
If you are required to access the devices to complete this scenario, the mouse cursor will use a hand symbol when moved over device icons. Clicking the icon will open a device terminal so you can interact with the hardware.
Open the Questions window and begin by clicking a question number. When you have completed answering all questions, click Done to continue.
Scenario
Use your UCS knowledge on Adapter errors ………………………………………configurations.
300-175 dumps exhibit
Current adapter status is?

  • A. Operable
  • B. Down
  • C. Inoperable
  • D. Unknown

Answer: A

NEW QUESTION 3
Where do you configure the VLAN when provisioning new VLANs in VM-FEX?

  • A. vCenter on the port group
  • B. Cisco UCS Manager on the port profile
  • C. Cisco UCS Manager on the service profile
  • D. vCenter on the host

Answer: B

NEW QUESTION 4
Which maintenance action releases the assigned chassis ID for future use?

  • A. Acknowledge chassis
  • B. Reset CMOS
  • C. Decommission chassis
  • D. Remove chassis

Answer: C

Explanation: Reference: http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/22/b_UCSM_GUI_Configura 86ACDE9D13C222A452

NEW QUESTION 5
Which policy is used to specify how Cisco UCS Manager should proceed for configuration changes that will have a service impact?

  • A. host firmware policy
  • B. maintenance policy
  • C. local disk policy
  • D. BIOS policy

Answer: B

NEW QUESTION 6
Which policy is used to update adapter firmware?

  • A. adapter policy
  • B. host firmware policy
  • C. management firmware policy
  • D. network control policy

Answer: B

NEW QUESTION 7
While configuring VM-FEX for Hyper-V, the virtual switch does not show up when you add the host with the port-profile management snap-in. Which statement describes the most likely cause?

  • A. SR-IOV is not enabled for the virtual switch inside Hyper-V.
  • B. Cisco Nexus 1000v is not enabled for the virtual switch.
  • C. Hyper-V requires Cisco UCS Manager to utilize Cisco Discovery Protocol on the vNIC profile.
  • D. An active VM is not associated with the port profile.
  • E. VM-FEX does not work with Hyper-V.
  • F. VM-FEX has been configured on the Catalyst switch but not in System Center yet.

Answer: A

NEW QUESTION 8
You must use a Cisco maintenance policy to create a deferred deployment that is independent of operating system actions. What must you include in the maintenance policy?

  • A. description
  • B. schedule
  • C. BIOS policy
  • D. reboot policy

Answer: D

NEW QUESTION 9
Which drive combination prevents you from provisioning RAID on Cisco UCS C-Series servers?

  • A. SAS HDD and SATA HDD
  • B. SAS SSD and SATA SSD
  • C. SATA HDD and SATA SSD
  • D. SAS HDD only
  • E. SATA HDD only

Answer: C

Explanation: Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/raid/configuration/guide/
RAID_GUIDE.pdf

NEW QUESTION 10
You are using UCS version 2.4 or later and need to advertise the identity of a server by using LLDP instead of CDP. Which policy in the vNIC template accomplishes this goal?

  • A. Ethernet adapter
  • B. network control
  • C. QoS
  • D. LAN connectivity

Answer: D

NEW QUESTION 11
Which addressing does Cisco UCS Manager use when communicating with Cisco UCS Central?

  • A. IP addresses of the UCS Fabric Interconnects
  • B. UCS CIMC
  • C. VMware ESXi server
  • D. IP address of the UCS KVM

Answer: A

NEW QUESTION 12
300-175 dumps exhibit

    Answer:

    Explanation: 300-175 dumps exhibit

    NEW QUESTION 13
    Which statement about Cisco Integrated Management Controller secure mode is true?

    • A. After you enable it, you cannot disable it.
    • B. After you enable it, you cannot downgrade the Cisco Integrated Management Controller firmware.
    • C. It verifies the OS before allowing it to boot.
    • D. The server must reboot to apply.

    Answer: A

    NEW QUESTION 14
    How does a dynamic vNIC get allocated?

    • A. Dynamic vNICs are assigned to VMs in VMware vCenter.
    • B. Dynamic vNICs can only be bound to the service profile through an updating template.
    • C. Dynamic vNICs are bound directly to a service profile.
    • D. Dynamic vNICs are assigned by binding a port profile to the service profile.

    Answer: C

    NEW QUESTION 15
    Refer to the exhibit.
    300-175 dumps exhibit
    Which description of the result is true?

    • A. An Ethernet monitoring session was created where traffic may be copied and forwarded to slot 1 port 9 for analysis.
    • B. An Ethernet monitoring session was created, activated and committed.
    • C. Ethernet traffic from slot 9 port 1 will be copied and forwarded to the destination SPAN port for analysis.
    • D. Ethernet traffic from slot 1 port 9 will be copied and forwarded to the destination SPAN port for analysis.

    Answer: A

    NEW QUESTION 16
    Which command sequence in the Cisco UCS C-Series rack server CLI sends tech support data to a TFTP server?

    • A. ucs-c250 / # scope cimcucs-c250 /cimc # scope tech-supportucs-c250 /cimc/tech-support # set path default.tar.gzucs-c250 /cimc/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /cimc/tech-support *# commit
    • B. ucs-c250 / # scope systemucs-c250 /system # scope tech-supportucs-c250 /system/tech-support # set path default.tar.gzucs-c250 /system/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /system/tech-support *# commit
    • C. ucs-c250 / # scope supportucs-c250 /support # scope tech-supportucs-c250 /support/tech-support # set path default.tar.gzucs-c250 /support/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /support/tech-support *# commit
    • D. ucs-c250 / # scope faultucs-c250 /fault # scope tech-supportucs-c250 /fault/tech-support # set path default.tar.gzucs-c250 /fault/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /fault/tech-support *# commit

    Answer: A

    Explanation: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/cli/config/guide/1-1-2/b_Cisco_CIMC_CLI This example creates a support data file and transfers the file to a TFTP server:
    Server# scope cimc
    Server /cimc # scope tech-support
    Server /cimc/tech-support # set tftp-ip 10.20.30.41
    Server /cimc/tech-support *# set path /user/user1/supportfile Server /cimc/tech-support *# commit Server
    /cimc/tech-support # start
    Reference:
    https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/cli/config/guide/1-1-2/b_Cisco_CIMC_CLI

    NEW QUESTION 17
    You need to install a Windows Server operating system that has MPIO enabled, to optimize connectivity with storage arrays.
    What is a valid prerequisite to perform this task?

    • A. iSCSImultipathing must be enabled on all of the vNICs and the physical adapters in the iSCSI initiator IP pools.
    • B. iSCSImultipathing must be disabled during the installation and re-enabled after MPIO is enabled on the host.
    • C. If there are multiple paths that are configured to the boot LUN, all of these paths must be enabled when the LUN is installed.
    • D. If there are multiple paths that are configured to the boot LUN, only one path must be enabled when the LUN is installed.

    Answer: D

    Explanation: If there are multiple paths configured to the boot LUN, only one path should be enabled when the LUN is installed
    Reference:
    https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configu

    NEW QUESTION 18
    Which Cisco UCS backup type results in an XML file that include all system and logical configuration settings?

    • A. system configuration
    • B. all configuration
    • C. full state
    • D. logical configuration

    Answer: B

    P.S. 2passeasy now are offering 100% pass ensure 300-175 dumps! All 300-175 exam questions have been updated with correct answers: https://www.2passeasy.com/dumps/300-175/ (349 New Questions)